The hypoxia chamber should be ideal for the experiments of the cultivation of mammalian cell culture
Material
SS + MS
Finishing
White Powder coating
Power Source
230Vac
Sizes
170ltr
Structure
Rectangular
Country of Origin
Made in India
The hypoxia chamber should be ideal for the experiments of thecultivation of mammalian cell culture, sperm/ovum, anaerobiccells, and all sorts of microbe cells, hatching/germinating andspecial tissues.· The inner chamber of the hypoxia chamber have volume of 50 / 100 / 150 /180 liters with Multi Gas Supply (N2 & CO2).· LuxMed® Hypoxia Chamber have monitoring system with analogconnection port designed to observe the status of equipment in realtime even in the far distance.· LuxMed® Hypoxia Chamber have LED display with Individual2-channel touch button operating panel.· Fast CO₂, O2, N2, temperature and humidity recovery withoutovershoot.· LuxMed® Hypoxia Chamber have In-line filters remove gasimpurities and contaminants.· LuxMed® Hypoxia Chamber have Fast heat-up, fast-recovery,reliable control.· Digital PID controlled Temperature range should be ambient+ 5 ℃ ~ 60 ℃ with accuracy of· ±0.1℃ (37℃) and resolution of 0.1 ℃· LuxMed® Hypoxia Chamber have 6 sides direct heatingsystem and the electric heating wire should be covered onall sides of the chamber to make good uniformity and toprovides fast heat-up & temperature recovery. Gentle airand moisture convection air and moisture in the chambershould be distributed naturally by 6 side heating and theair circulation fan.· LuxMed® Hypoxia Chamber Independently validatedovernight cycle ensures complete elimination of allbiological contaminants.· No need to remove IR CO2 sensor.· LuxMed® Hypoxia Chamber have 125 ℃ dry hot air sterilization, conforms to the International standards for dry heat sterilization andproven to effectively deactivate normally-resistant fungi, bacterial spore and vegetative cells. Nontoxic and noncorrosive sterilization thatcompletes within 12 hours leaving the chamber cool and dry at the end of the cycle.· The 3 parts of heating section should be controlled and calibrated individually by 3 individual temperature sensors.· LuxMed® Hypoxia Chamber have antimicrobial powder coating to eliminates 99.9% of surface bacteria within 24 hours of exposure.· LuxMed® Hypoxia Chamber be dry wall and air jacket system with warm air from heating wire which preserved in space between thechamber and the insulation layer to helps temperature recover faster and minimize heat loss.· LuxMed® Hypoxia Chamber have lower gas consumption and lower heat loss.·The system insulation should not require regular maintenance.· LuxMed® Hypoxia Chamber have dual beam IR CO2 Sensor for fast & precise detection for CO2 gas regardless of temperature andhumidity.· Microprocessor controlled CO2 range should be 0%~20% with Accuracy of ± 0.1 % (5%/37℃), resolution of 0.1% and Inlet pressurerange of 0.5 ~ 0.6 bar.· LuxMed® Hypoxia Chamber have natural humidification using water tray.· LuxMed® Hypoxia Chamber have O2 Range of 0.6 ~ 20% with zirconium dioxide sensor.· LuxMed® Hypoxia Chamber have circulation fan to delivers the moisture formed from the water to the entire chamber.· LuxMed® Hypoxia Chamber have front door heater & frame heater to prevent condensation in the chamber and on the glass door.· LuxMed® Hypoxia Chamber have ULPA/HEPA filtration. Filtered air circulates across the humidity pan to accelerate the humidifyingprocess.
By simulating the growth environment of microorganisms, tissues and cells, the three-gas incubator p
Material
MS+SS
Finishing
SS
Power Source
230Vac
Sizes
500ltr
Structure
Metal
Country of Origin
Made in India
LuxMed® Tri-Gas CO2 Incubator / Hypoxia Incubator Chamber By simulating the growth environment of microorganisms, tissues and cells, the three-gas incubator provides stable temperature and humidity, carbon dioxide concentration and oxygen concentration, and is widely used for the propagation and cultivation of cells, tissue cultures and some special microorganisms. "Application: Tri-gas incubator is commonly used in microbial culture, cell dynamics research, collection of mammalian cell secretions, carcinogenic or toxicological effects of various physical and chemical factors, research and production of antigens, cultivation of hybridoma cells to produce antibodies, in vitro fertilization (IVF), stem cells, tissue engineering and other research fields. Features: 1. IR infrared sensor, using dual-channel dual-filter infrared technology. 2. O2 sensor was used for oxygen concentration information acquisition. 3. The inner tank is designed with fully rounded corners and the surface is made of 304 stainless steel with electrochemical treatment. 4. The bottom water reservoir design eliminates the need for repeated water replenishment, saving time. 5. The water level alarm design alerts the operator to refill water in time, providing more comprehensive protection for the samples. 6. Equipped with a gas switching function, it can connect to two bottles of carbon dioxide gas simultaneously. 7. Equipped with leakage current and over-voltage protectors. Features over-temperature, under-temperature, over-concentration and under-concentration alarms."